10 %

$1,954.00 $1,753.23 inc GST

(2 customer reviews)
G390SS
  • Supply and Install
  • AquaMAX 390 stainless steel hot water unit
  • Price includes the issuing of a Compliance Certificate
  • 390 litres in the first hour
  • Natural gas
  • External use
  • 12 Year warranty

 

AquaMAX 390 Stainless Steel Gas Storage Hot Water System

G390SS

Supplied and Installed

The standard installation price allows for the disconnection of the existing HWS (recessed or free standing), the installation of the new HWS, installation of the temperature/pressure relief valve drain, any necessary alterations to the gas, cold water, hot water connections (using the existing gas cock, duo valve & concrete slab) and the commissioning of the new HWS.

Change over existing external gas mains pressure storage hot water service with a gas mains pressure storage hot water service in the same location.

Price also includes the issuing of a Compliance Certificate.

All work to comply with Australian Standard Gas Installations, AS5601 – 2004, Electrical Standard AS/NZS 3000 – 2000, Local Municipal Regulations and Manufacturer’s installation instructions.

Features

The AquaMAX 390 patented in-built mixing valve gives you up to 390 Litres first hour delivery with a 5 Star Energy Rating and 12 Year cylinder warranty

Power : natural gas
Location : external
Cylinder size : 155 litres
First hour delivery: 390 litres first hour
Recovery rating : 185 litres per hour at 45deg rise

Technical Information

Unit height : 1635 mm
Unit width : 520 mm
Unit depth : 610 mm
Water outlet : 370 mm
Water inlet : 370 mm
Gas/power inlet: 370 mm
Water inlet : 20mm (3/4″) female
Water outlet : 20mm (3/4″) female
Gas connection : 15mm (1/2″) compression
Ptr valve : 1400 kpa/99deg c

Warranty

Product Warranty: 12 Years

 

Gas storage hot water system?

Aquamax 390SS Diagram
Special Notes

SPECIAL NOTES:
All work to comply with Australian StandardTM Gas Installations, AS5601 – 2004, Electrical Standard AS/NZS 3000 – 2000, Local Municipal Regulations and Manufacturer’s installation instructions.
1. The contractor must check cold water mains supply pressure and if it exceeds manufacturers' recommended maximum, an approved pressure limiting valve MUST be fitted. (Variation must be signed by Customer). See Extras.
2. If the existing HWS is recessed into the wall and the new HWS is suitable to install into the existing opening without any alteration to the opening, the replacement HWS can be installed into this opening.
OR
3. If the new unit is not suitable to install into the existing opening or is unable to be installed into the existing opening without alteration, see Extras for an additional cost to seal the opening left in the wall by the original HWS with unpainted fibro cement sheet.
Note to all Customers: Veeken Plumbing cannot accept responsibility for any defects that may arise in the existing reticulation system. In the event that defects do arise Veeken Plumbing can rectify at the Customer's own expense.

Share your thoughts!

5 out of 5 stars

2 reviews

Let us know what you think...

What others are saying

  1. Mick - Ringwood

    Great job

    Mick – Ringwood

    Water heater works really well

    (0) (0)

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  2. Martin - Croydon

    Best water heater on the market

    Martin – Croydon

    I shopped around and did my research and found that the Aquamax 390 stainless steel water heater is the best on the market

    (0) (0)

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

×

Login

Register

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

Continue as a Guest

Don't have an account? Sign Up

×